-
High Availability and Redundancy
N+1 / 2N power and cooling redundancy — Tier III+ uptime standard
Dual utility feeds from separate substations plus generator backup
Non-blocking spine-leaf network topology with congestion control
Modular power blocks — phased deployment from Day 1 through full 30 MW build-out
-
Advanced Security Measures
Multi-layer perimeter with CCTV and 24×7 manned security
Mantrap entry with biometric access controls
Tenant-specific cage and suite isolation — physical and logical separation
Continuous vulnerability management, patch governance, and threat detection
-
Robust Infrastructure
G+5, 250,000 sq. ft. purpose-built structure — not a converted facility
Floor loading up to 1,850 kg/sqm for high-density AI rack weights
3,000+ racks spanning standard to ultra-high-density (240 kW+) configurations
In-house GIS substation engineered for future expansion
-
Carrier-Neutral Connectivity
Multiple ISP and dark fiber entry options — no single-carrier lock-in
Proximity to Chennai submarine cable landing stations (IMEWE, SMW4, Bay of Bengal Gateway)
BGP multi-homing with redundant uplinks
Dark fiber and dedicated wavelength options for hyperscalers
-
Environmental Controls
Direct-to-Chip and Rear-Door Heat Exchanger cooling with configurable CDUs
Coolant temperature, pressure, and flow monitoring with leak detection
PUE target below 1.3, ahead of the industry average of 1.57
Real-time environmental telemetry through DCIM, BMS, and EPMS
-
Managed Services
24×7 NOC/SOC with SLA-backed power and cooling operations
Managed GPU cloud, Kubernetes, and Slurm cluster support
MLOps pipelines, inference endpoints, and observability tooling
GPU refresh cycle management and ongoing capacity planning
-
Compliance and Certifications
ISO 27001 controls for information security management
MeitY empanelment eligible for government and regulated workloads
SOC-aligned audit packages for BFSI and healthcare data residency
Tier III+ design aligned to Uptime Institute standards
-
Scalability and Flexibility
Four deployment models — from single rack to whole-campus 30 MW tenancy
Reserved capacity blocks with contractual expansion rights
Build-to-suit MEP systems for anchor tenants and dedicated halls
Scale from 1 rack to 5 MW without migrating infrastructure
-
Expert Support and Consultancy
Structured 6-step onboarding from chipset BoM discovery to production operations
Per-rack OEM validation covering power, thermal, and network topology
Factory and Site Acceptance Testing (FAT/SAT) before go-live
Two decades of Indian mission-critical infrastructure operating experience
-
Sustainable Practices
LEED Gold sustainability certification targeted
PUE target below 1.3, against an industry average of 1.57
ESG-aligned reporting built into compliance documentation
Energy-efficient Direct-to-Chip and RDHx cooling reducing mechanical load